The long{{0}}term working temperature of DJYPVP cable conductors: PVC has two types: 70 degree and 105 degree ; polyethylene insulation is 70 degree ; cross-linked polyvinyl chloride insulation is 90 degree . The cable is allowed to be fixedly laid and used under the condition of ambient temperature -40 degree -50 degree , and the environment during laying should not be lower than 0 degree . For cables with copper tape shielding structure, the bending radius when laying should not be less than 12 times the outer diameter of the cable, and the bending radius when laying other cables should not be less than 6 times the outer diameter of the cable.
DJYPVP code meaning (DJYPVP2x2x1.0):
D - computer cable
J - twisted
Y——The insulating material is polyethylene
P - shielding (here refers to the shielding of the wire to the copper wire).
V——The sheath material is PVC
p - shielding (total shielding, copper wire) if P2 is copper tape shielding
The 2 in front refers to two pairs
The latter 2 is the number of cores per pair
1.0 is the cross section of each core conductor